Reliability Test Capabilities

Tyndall’s fully equipped reliability test laboratory offers the following test capabilities:

Air-to-air Thermal Shock Testing
from –75°C to + 220°C2 test chambers
test space = 120 litres, max load = 5 Kg

Temperature Cycling
from 70°C to + 180°C at up to 20°C per min.
test space = 100 litres, max load = 5 kg

Temperature / Humidity Testing
from -70°C to + 180°C and 3% RH to 99% RH
cyclic and steady state tests
3 test chambers, test space = up to 300 litres

Thermal Shock & Humidity Test Chambers

 

Highly Accelerated Stress Testing (HAST)
from 100°C to 150°C, 50% RH to 100% RH
test space = 22 litres. 

Burn-in Testing
up to 180°C, test space = up to 300 litres

High & Low Temperature Storage Tests
from – 70°C to +180°Ctest space = up to 300 litres

HAST, Thermal Cycling & Humidity Chambers

 

Vibration Testing
fixed frequency tests
swept sinusoidal & random frequency tests (10 Hz to 2KHz)
Max Acceleration = 100 g, Max Force = 489 N

Mechanical Shock Testing
half-sine & square wave shock pulses
up to 100 g, repeated automatic pulsing

Drop / Shock Testing
Up to 3,000 g, min pulse = 0.2 ms.
152 X 152 mm sample area, Max weight = 23 Kg 

Salt Spray Testing
Temp range = ambient to 55°C.
Test Space Volume = 400 litres.

LDS DVC4000 Vibration Test System

Free-fall Mechanical Shock Test System




 

© 1995-2006 Tyndall National Institute. All Rights Reserved E&OE | Privacy Statement | Updated: Wednesday, 03-Dec-2008 18:09:44 GMT